Wireforms for HVAC and refrigeration: vibration and corrosion

Material and coating choices for wire parts that live in wet, vibrating air paths, and the contact points where both failures start.

QKQumek Engineering Desk··9 min read·Updated
R 4.0Ø 3.00

Key takeaways

  • In HVAC and refrigeration, corrosion and fatigue usually start at the same place: a metal to metal contact point.
  • Condensate is the design condition, not the exception. Assume the part is wet for part of every cycle.
  • Match the finish to the zone, and keep dissimilar metals apart where water can bridge them.
  • Vibration should be designed out through stiffness and routing before a material is upgraded.

Where wireforms sit in an air path

Wire shows up all over an HVAC or refrigeration unit because it is cheap, stiff and open. Fan guards, coil supports, capillary clips, compressor mount springs, damper linkages, filter frames, drain pan clips and thermostat springs are all formed wire. Most of them are secondary parts in the bill of materials and primary parts in the failure report.

The duty is unusual. The part sits in moving air, at a temperature that cycles, in a stream that may carry dust, and in a cabinet that collects condensate. It is also expected to be quiet. A wire guard that rattles at low fan speed is a warranty call even if the metal is sound.

Corrosion starts where water sits or where two metals touch. Fatigue starts where a vibrating part is restrained. Both are designed in or out at the drawing stage.

Condensate, chlorides and galvanic couples

An evaporator coil runs wet for much of its life. Water collects on the fins, runs to the drain pan and splashes onto the supports. That water is not pure. It picks up dust, biological growth and, in coastal or industrial sites, chloride. A wire support that looked adequate on a dry bench is now in a shallow electrolytic cell.

The most common mistake is a zinc plated steel clip touching an aluminium fin pack or a copper tube. Zinc and aluminium sit at different positions in the galvanic series, and water bridges the joint. The aluminium becomes the anode and corrodes around the contact, while the steel clip keeps its shape and hides the damage. A coated clip, an isolating grommet or an aluminium support removes the couple.

Stainless is not automatically the answer. A 304 grade can pit in a chloride bearing condensate, especially in a crevice under a clip or at a tight bend where the stress is high. A 316 grade or a polymer isolated contact is the usual response where chlorides are expected.

Crevices deserve their own line in the review. Two wires twisted together, a clip closed over a tube and a coating that has lifted at an edge all create a gap where water sits and oxygen cannot refresh. That is where pitting begins, even on a good alloy.

Water finds the contact

Design the drain path before choosing the coating. A part that holds water will corrode whatever it is made from, and a part that drains will last in a modest finish.

Vibration: the failure that starts at a contact

A fan guard, a coil support or a capillary clip is a spring whether or not the drawing calls it one. It has a natural frequency, and if that frequency sits near the running speed of a fan or a compressor, the part will amplify the excitation. An illustrative fan at 900 rpm gives 15 Hz. A bracket with a natural frequency close to that will move far more than its static load suggests.

Fatigue cracks usually start where relative movement is restrained. A wire that passes through a hole, a clip that pinches a tube, a hook that rests on a bracket: each of those is a fretting point. Small oscillating movement wears the coating, exposes bare metal, creates a corrosion pit and then a crack. The two failure modes feed each other.

The first fix is stiffness, not material. Shorten the unsupported span, add a leg or a gusset, change the routing so the mass sits closer to the mounting, or add a compliant clip that lets the part move as a whole instead of flexing at a joint. The second fix is isolation: a rubber or polymer sleeve at the contact spreads the load, damps the movement and separates the metals.

Only after those changes should the alloy be upgraded. A stronger wire in a flexible layout will still fatigue, and it will cost more while it does so.

Match the material to the zone

An HVAC unit has several microclimates, and one finish rarely suits all of them. The table below is a starting point for the conversation with the designer and the coating supplier, not a substitute for a test in the actual unit.

Exposure zones and the material or finish that suits them
ZoneExposureMaterial and finishFailure to watch
Evaporator coil supportCondensate, constant wetAluminium or 304 with isolating clipsGalvanic attack at the steel contact
Outdoor condenser guardRain, sun, coastal chlorideHot dip galvanised steel or 316Coating damage at cut ends
Compressor mountOil, refrigerant, vibrationZinc flake coated steel or stainlessFretting and fatigue at the hook
Drain pan clipStanding water and biofilm316 or a polymer coated steelCrevice corrosion under the coating
Fan guardDust, occasional wash downPowder coated steel or stainlessCoating erosion and balance

The zone matters more than the average site condition. A clip that stays wet is a different specification from a guard that dries between cycles.

What each coating does under a wet, vibrating duty

Zinc plating is the cheapest route and the weakest in a wet zone. It protects steel by sacrificing itself, so it works well until the layer is consumed, scratched or blocked by a tight contact. In a condensate stream it is a short term answer.

Powder coating gives a thicker barrier and a colour, and it hides the wire. Its weakness is the edge and the bend. The film thins on an outside radius, and a chip becomes an undercut where water creeps along the interface. Once that starts, the coating can hide a corrosion cell that is larger than the visible damage.

Zinc flake coatings sit between the two. They are thin, they tolerate tight tolerances and they protect at cut edges better than paint, which makes them useful on clips and tines where a thick film would change the fit. Abrasion at a contact point is still a limit.

Hot dip galvanising gives a thick, sacrificial layer that suits outdoor frames and guards. It is not a precision finish. Threads need clearing, small holes can bridge and the coating adds thickness that the drawing has to allow for.

Stainless removes the coating question and introduces others: cost, galling at threads, and chloride pitting if the grade is wrong. Use it where the part is difficult to recoat and the environment is known.

The design details that decide life

A few small calls do more for life than a change of alloy.

  • Put the low point where water can leave. A U bend that holds a cup of condensate will corrode from the inside.
  • Break the metal to metal contact at every clip with a sleeve, a coating or a change of material.
  • Keep the wire away from sharp fin edges and from the tube wall, so vibration does not wear through either part.
  • Increase the bend radius at any point that flexes. A tight radius concentrates strain and is the first place a crack appears.
  • Route the part so the mass sits near a mounting point, and avoid long unsupported legs in the air stream.
  • Leave room for the coating. A powder film on a tight fit can turn a clearance into an interference.

What to test and what to put on the drawing

A salt spray test to ISO 9227 is a useful comparison between finishes, but it is not a prediction of life in a condensate stream. The electrolyte, the wet and dry cycle and the galvanic couple in the real unit are different. Use the test to qualify a coating process, then confirm the part in the unit.

Vibration testing should reproduce the mounting and the running speed. A sine sweep finds the natural frequencies, and a dwell at the running speed shows whether the part will survive. Add a check of the contact points after the test, because fretting damage can be present before a crack is visible.

On the drawing, state the wire diameter and grade, the finish and its thickness, the masked areas, the critical fit dimensions and the coating standard. Add the zone and the cleaning method the unit will see. If the part is powder coated, say whether the coating must cover the cut ends, because that call changes the process.

Ask for a first article that records coating thickness on a bend and the bend radii. Those two records catch most field problems.

Sending the part out for quote

Send the drawing, the wire diameter and grade, the finish, the annual volume, the unit zone and the cleaning regime. Say whether the part is indoors, outdoors, coastal or wash down. Add the vibration source and its running speed if the part is close to a fan or a compressor.

A supplier can then propose the forming route and the finish together, which is the point. A part that is cheap to form and expensive to coat is not cheap, and a part that is over-specified in stainless may be beaten by a coated steel design with a better drain path.

The best HVAC wireform is usually the one that is stiff enough, drains well and separates its metals. Those three calls cost less than an upgrade to a higher alloy.

Frequently asked questions

Is stainless steel always better than zinc plated steel for HVAC wireforms?

No. Stainless resists many environments better, but 304 can pit in chloride bearing condensate, and the cost is higher. A zinc flake or powder coated steel part with a good drain path and isolated contacts can be the better choice, especially where the part dries between cycles.

Why do wire clips fail where they touch a coil?

That contact is a crevice, a galvanic couple and a fretting point at the same time. Water sits in the gap, two dissimilar metals share an electrolyte, and vibration wears the coating. Isolating the contact and improving drainage addresses all three.

How do I stop a fan guard from vibrating?

Raise the stiffness or move the mass. Shorten unsupported spans, add a leg or gusset, and keep the guard away from the fan running frequency. Isolation at the mounting points helps, but it will not fix a guard that is already too flexible.

Does a salt spray result prove the part will last outdoors?

It proves the coating process met a defined test. It does not reproduce the wet and dry cycle, the galvanic couple or the abrasion of a real unit. Use it as a process check and confirm the design in the actual cabinet.

Sources and further reading

  • ISO 9227:2022, Corrosion tests in artificial atmospheres, salt spray tests
  • ISO 2768-1:1989, General tolerances, linear and angular dimensions
  • Qumek drawing review and DFM notes for formed wire parts
QK

Qumek Engineering Desk

Engineering team

The engineering team behind Qumek drawings, DFM notes, tolerances and inspection standards. Every guide is reviewed against the drawings and processes used on live programmes.

Have a wire part in a wet air path?

Send the drawing, the zone and the vibration source. The engineering desk will reply with a written note on the material, coating and contact points.

Send a drawing

The Qumek dispatch

One useful email a month

Drawing notes, supplier checks, tariff changes and the questions buyers keep asking. No newsletter filler, no daily drip.

One email a month. No spam, no list sharing.