Key takeaways
- Force at a stated stroke, current at a stated voltage and coil temperature describe one actuator, so verify them as a set.
- Copper resistance rises with temperature, so a hot coil draws less current at a fixed voltage and produces less force.
- Overlay the return spring load line on the force stroke curve to find the position the actuator can actually hold.
- Accept the force at the minimum supply voltage and maximum ambient, after thermal equilibrium, not on a cold bench.
Three curves, one actuator
A solenoid is specified by a force at a stroke, but the force depends on the current, and the current depends on the coil temperature. The three curves belong together. A force stroke curve at one current, a current rise curve at one voltage and a temperature rise curve at one duty cycle describe the same actuator from three sides.
A bench check at 20 °C with a coil that has run for ten seconds is the easiest test to pass and the least useful. In service the coil sits at its equilibrium temperature, the copper resistance is higher, the current at a fixed voltage is lower and the force at the end of the stroke is lower again. The verification has to reproduce that state, or the acceptance number describes a different product.
Reading a force stroke curve
A force stroke curve plots pull against armature position at a held current. The shape comes from the magnetic circuit: the force is usually highest near the seated position and falls as the air gap opens. The curve only means something when the current, the coil temperature, the stroke datum and the return spring are stated with it.
The worst point is not always at the start. In a short stroke actuator the minimum may sit mid travel where the magnetic force and the spring load cross. Plot the spring load line on the same axes, because the actuator can only hold a position where the magnetic force exceeds the spring. If the crossing point sits close to the required stroke, tolerance in the spring or the coil will move it out of the working range.
State where stroke zero is. Some drawings measure from the fully seated armature, others from the rest stop with the return spring fitted. A force quoted at 2 mm means nothing until the datum is fixed, and the two conventions can differ by the residual gap and the spring preload.
Where the heat comes from
Copper loss dominates. The coil dissipates current squared times resistance, and almost all of that heat leaves through the bobbin, the housing and the mounting. Hysteresis and eddy current loss are small in a DC coil, but they matter when the coil is driven with pulse width modulation or AC.
As the winding heats, resistance rises. At a fixed voltage the current falls, so the force falls with it. The coil is self limiting to a degree, but the actuator loses the margin the designer counted on. A coil rated for a 55 K rise at 20 °C ambient is not at 20 °C when the panel around it sits at 50 °C.
Temperature rise is a coil number; hot force is an actuator number
A coil can meet its insulation class and still leave the mechanism short of force. Report the force at the equilibrium temperature as well as the temperature rise, or the two tests can both pass while the product fails.
Duty cycle and thermal equilibrium
Duty cycle converts a continuous rating into an intermittent one. A coil that can run continuously at one watt may run at two or three times that loss for a short on time if the off time lets the winding cool. The energy average matters, not the instantaneous current.
The mounting is part of the thermal circuit. A coil clamped to a metal bracket conducts heat away; the same coil in still air inside a sealed housing runs hotter. Orientation, nearby heat sources and altitude all move the equilibrium. The duty cycle should be stated with the mounting and the ambient, or the number cannot be checked.
The cold and hot verification set
The same actuator has to be measured twice, because the cold check proves the mechanism and the hot check proves the application. The table shows what to record at each state.
| Parameter | Cold check | Hot check | Acceptance basis |
|---|---|---|---|
| Coil resistance | At a stated reference temperature | After thermal equilibrium | Corrected to 20 °C for comparison |
| Current at rated voltage | Record the value | Record the lower hot value | Minimum current for the required force |
| Force at rated stroke | Sweep the full stroke | Repeat at the worst point | Minimum at minimum supply voltage |
| Holding force at seat | Record the peak | Record after soak | Above the load with margin |
| Temperature rise | Not applicable | Winding and housing | Within the insulation class |
| Operate and release time | At rated voltage | At voltage limits | Inside the cycle requirement |
| Insulation resistance | After the build | After the soak | Above the agreed minimum |
The values are application specific. Record the method, the ambient and the soak time with every result.
How to run the verification
The sequence matters, because a force measured before the coil has stabilised will be optimistic. Run the actuator at its specified duty and ambient until the resistance change over a fixed interval is small enough to call equilibrium, then measure.
- 01
Stabilise the coil
Run at the specified duty, voltage and ambient until the winding temperature stops climbing.
- 02
Measure resistance
Use the resistance change from the reference reading to calculate the mean winding temperature.
- 03
Sweep the stroke
Hold current constant and record force at each position with a load cell aligned to the axis.
- 04
Add the spring
Overlay the return spring load line and find the crossing point with the force curve.
- 05
Repeat at the limits
Run again at the minimum and maximum supply voltage and at the ambient extremes.
What moves the number
Five things account for most of the difference between a good bench result and a field result. Check each one before the design is released.
- Supply voltage tolerance, including the drop during inrush from a shared rail.
- Coil temperature at equilibrium, which sets the resistance and the current.
- Air gap and residual gap, which change the magnetic circuit and the force at the seat.
- Friction in the bore and the plunger guide, which consumes force before the load sees it.
- Return spring tolerance and preload, which set the position where the force crosses the load.
- Mounting and heat sinking, which decide how hot the coil runs in the application.
Specifying acceptance
Specify the force at the rated stroke at the minimum supply voltage and the maximum ambient, after thermal equilibrium. Add the duty cycle, the mounting condition and the temperature rise limit. A single force figure at room temperature cannot be verified in a way that protects the application.
State the measurement method as well: the stroke datum, whether current or voltage is held, the load cell direction and the soak time. Then ask for the trace, not only the pass mark, so the shape of the curve is visible. A part that passes at one point but has a flat or falling curve can still fail in the mechanism.
Frequently asked questions
Why does solenoid force drop when the coil gets hot?
Copper resistance rises with temperature. At a fixed supply voltage the current falls, so the ampere turns fall and the magnetic force falls with them. The effect is small at first and grows as the coil approaches its equilibrium temperature.
Should force be measured at constant current or constant voltage?
Both have a use. Constant current isolates the magnetic circuit and is better for comparing designs. Constant voltage reproduces the application, where the current falls as the coil heats. Specify which one the number refers to.
What duty cycle should I specify?
State the on time, the off time and the ambient, not only a percentage. A 25 per cent duty cycle with a two second on time is a different thermal problem from 25 per cent with a two minute on time.
How is coil temperature measured during a test?
The usual method is to measure resistance before and after the run and calculate the mean winding temperature from the change. A thermocouple on the outside of the coil reads lower and responds slowly, so it is better for the housing than for the winding.
Sources and further reading
- IEC 60068-2-1:2007, Environmental testing, cold
- IEC 60068-2-2:2007, Environmental testing, dry heat
- Qumek coil and solenoid verification notes
Qumek Engineering Desk
Engineering team
The engineering team behind Qumek drawings, DFM notes, tolerances and inspection standards. Every guide is reviewed against the drawings and processes used on live programmes.