Key takeaways
- Tracking is a surface failure; dielectric breakdown is a through thickness failure.
- CTI is measured on a small specimen and does not describe a contaminated housing in service.
- Dielectric strength falls as the wall gets thicker, so a kV/mm figure needs a thickness beside it.
- Specify the standard, the grade and the wall thickness on the drawing, not just a material name.
Two failure modes, two tests
An insulating plastic can fail in two ways. A conductive path can form across its surface, usually along a track of contamination and moisture, and the current then flows where the design assumed it could not. Or the material can break down through its thickness under a voltage high enough to exceed its dielectric strength.
The first failure is a tracking failure, described by the comparative tracking index. The second is a breakdown failure, described by dielectric strength. They are measured with different tests, they depend on different variables, and a material that is good at one is not automatically good at the other.
Confusing the two leads to the wrong material call. A housing can have an excellent dielectric strength and a modest tracking index, which matters if the design puts two live parts close together on a contaminated surface.
A design review should ask which of the two failures the product is exposed to, then check the drawing for the input that controls it. Most spacing arguments come from a design that answered one question and assumed the other.
What CTI measures
The comparative tracking index test places a pair of electrodes on a small flat specimen, applies a voltage and drips a conductive solution onto the surface between them. The voltage is reduced in steps until the surface tracks. The result is expressed in volts and describes the resistance of the material surface to tracking under that condition.
The number is comparative, not absolute. It compares materials on a standard specimen under a standard contaminant. It does not tell you what happens on a ribbed housing with dust, humidity and a temperature rise, which is why standards separate the material index from the creepage distance the design must provide.
The test also depends on the specimen condition. A conditioned specimen and a dry specimen can give different results, and the thickness of the specimen matters less than its surface state. Ask which condition the figure was measured under.
The test is also sensitive to the electrode geometry and the dropper rate, which is why the standard fixes both. A result quoted without the standard reference is hard to compare with another supplier's figure, even when both numbers look similar.
Reading the groups
Results are grouped into performance level categories. The highest group covers materials at 600 V and above, the next covers 400 to 599 V, then 250 to 399 V, then 175 to 249 V, and the lowest covers 100 to 174 V. A material in a higher group allows a shorter creepage distance for the same working voltage and pollution degree.
The gap between groups is not linear in cost. Moving from a 250 V material to a 600 V material can change the polymer family, the filler package and the price, and it may change the flame rating and the impact behaviour at the same time.
Read the group together with the working voltage. A design at low voltage with wide spacing may be safe in the lowest group. A compact design at mains voltage may need the higher group simply to fit the creepage into the available wall.
Group letters are sometimes quoted without the standard behind them. Ask for the standard and the test report, then check that the figure applies to the grade and the colour you specified.
Dielectric strength and thickness
Dielectric strength is the voltage at which the material breaks down, divided by the thickness of the specimen. It is usually quoted in kilovolts per millimetre, and the figure is only valid for the thickness and the test condition that produced it.
The relationship with thickness is not linear. A thin specimen often shows a higher strength per millimetre than a thick one, because the probability of a defect in the stressed volume rises with thickness. Designers who multiply a headline kV/mm figure by a wall thickness usually overestimate the withstand of the part.
The test condition matters as well. A short duration test at power frequency, an impulse test and a step test produce different numbers. The specification should name the standard, the waveform and the duration, and the acceptance should be a withstand voltage at the wall thickness used.
Moisture changes the answer. A dry specimen withstands more than a conditioned one, and a housing that absorbs water will move toward the conditioned result in service. For a humid environment, the conditioned figure is the one to use.
From index to creepage and clearance
The material index feeds the creepage distance, not the clearance. Clearance is the shortest path through air and depends on the working voltage, the overvoltage category and the pollution degree. Creepage is the path along the surface and depends on the same factors plus the material group.
That is why a higher group material is worth money in a compact product. It allows a shorter surface path for the same voltage, which can remove a rib, shorten a wall or fit a terminal into a smaller pocket. In a large product the saving may be zero, because the spacing is already generous.
Pollution degree has as much effect as the material. A sealed housing may be assessed at a lower pollution degree than an open one, and that changes the creepage table lookup. If the seal fails in service, the assumption fails with it.
Creepage is measured along the surface, so a rib adds path length without adding width. That is why a moulded groove or a standing rib can solve a spacing problem that a flat wall cannot, provided the rib can be moulded and the tool can release it.
Material families
PA66 and PBT dominate electrical housings, and both can be supplied in grades that reach the higher groups. PC is common where impact and appearance matter, with a tracking index that is usually lower. PPS appears where temperature and chemical resistance matter more than cost, and its tracking behaviour varies widely with the filler package.
The table below is a starting point for a conversation with the material supplier, not a substitute for the data sheet for the exact grade.
A grade that meets a flame rating at 1.5 mm may not meet it at 0.8 mm, and the tracking index can move with the flame package. Treat the two requirements as a pair and check them on the same data sheet, at the same thickness.
| Family | Typical CTI band | Moisture | Where it fits |
|---|---|---|---|
| PA66 | Often 400 to 600 V | Absorbs moisture, dimensions move | Tough housings with good electrical grades |
| PBT | Often 400 to 600 V | Low absorption, stable dimensions | Precision parts and terminal blocks |
| PC | Often 250 to 400 V | Low absorption, stress cracking risk | Impact resistant covers and enclosures |
| PPS | Grade dependent, often lower | Very low absorption | High temperature and chemical exposure |
| PA6 | Often 400 to 600 V | Higher absorption than PA66 | General industrial parts |
Bands are indicative for common grades. The data sheet for the exact grade, colour and thickness governs.
Specifying it on the drawing
A drawing that says PA66 does not specify an electrical material. It names a family. The drawing should name the grade, the standard behind the tracking figure, the minimum value, and the thickness at which the flame and electrical ratings apply.
Add the creepage and clearance requirement as a dimension or as a note with the pollution degree and the working voltage. An inspector can measure a distance. An inspector cannot measure an intention.
Finally, control the change. A colour change, a filler change or a switch to a second source can move the tracking index without moving any dimension on the drawing. Treat any material change as an engineering change with a new data sheet and, where the risk justifies it, a new test.
The same discipline applies to incoming inspection. If the drawing names a grade and a minimum index, the goods in check should confirm the grade on the label and on the certificate, not just the colour and the quantity.
Index on the drawing, distance on the part
The material index tells the designer how much surface path is needed. The drawing has to turn that into a distance someone can measure.
Frequently asked questions
What is the difference between CTI and dielectric strength?
CTI describes resistance to tracking across the surface under a contaminated condition and is expressed in volts. Dielectric strength describes breakdown through the material and is expressed in kilovolts per millimetre. They are separate tests and separate design inputs.
Is a higher CTI always better?
It allows shorter creepage for the same voltage, which can save space. It may also cost more, change the impact behaviour or narrow the choice of grades with the flame rating you need. The right value comes from the working voltage, the pollution degree and the space available.
Can I use the data sheet dielectric strength directly?
Only at the thickness and condition the figure was measured at. Dielectric strength per millimetre falls with thickness, so multiplying a headline figure by a wall thickness usually overestimates the withstand. Specify a withstand test at the wall used.
Does colour affect electrical properties?
It can. Pigments and masterbatches change the additive package, and some colours are harder to stabilise. Where a flame or tracking rating matters, confirm that the rating applies to the colour specified, and treat a colour change as a material change.
Sources and further reading
- IEC 60112, Method for the determination of the proof and the comparative tracking indices of solid insulating materials
- IEC 60664-1, Insulation coordination for equipment within low voltage supply systems
- IEC 60243-1, Electric strength of insulating materials, test methods
Qumek Engineering Desk
Engineering team
The engineering team behind Qumek drawings, DFM notes, tolerances and inspection standards. Every guide is reviewed against the drawings and processes used on live programmes.