Connector insertion and withdrawal force

How to set a force window that protects the contacts, suits the user and still passes the test, with the force budget, test method and acceptance calls that matter.

QKQumek Engineering Desk··8 min read·Updated
Ø 13.010 µm Sn

Key takeaways

  • Insertion force and withdrawal force are different requirements and should be specified separately.
  • Most of the mating force comes from contact friction, multiplied by the number of circuits, plus seals and latches.
  • Test the finished connector at the standard rate, with the real alignment, not a bare contact pair.
  • A force that is too low is as much a risk as one that is too high: low normal force leads to resistance and fretting.

What the numbers mean

Insertion force is the peak force needed to mate a connector. Withdrawal force is the force needed to separate it. Mating force usually means the insertion figure, and unmating force means the withdrawal figure. The terms are close enough that a drawing should use one pair and define it.

Neither number is a single value. The force changes through the travel: it rises as the contacts engage, falls as they settle, and rises again when a seal or a latch is compressed. The peak is what the user feels and what the test records. The average is useful for the mechanism, but the peak decides whether the housing cracks.

The force also changes with the number of mates. A new connector is usually stiffer than one that has been mated twenty times. A specification that quotes only the first mate is incomplete.

Where the force goes

The main term is contact friction. Each contact spring presses on the mating pin with a normal force, and the sliding surfaces resist with a friction force. Multiply by the number of contacts and add the effect of any wipe or lead-in geometry.

Seals add a second term. An interfacial seal, a cable gland or a radial O-ring is compressed during mating, and that compression is felt as force. A sealed connector can need noticeably more force than the same housing without seals.

Latches and locking rings add a third term. A push-pull latch, a bayonet ring or a screw coupling has its own force profile, and the peak often sits at the point where the latch rides over its detent. A connector with a secondary lock can have a separate, smaller force event after the main contacts engage.

Finally, misalignment adds force. If the two halves are not parallel, the contacts bind and the force rises. A floating panel mount or a lead-in chamfer reduces this term. A rigid, badly aligned installation can double the force that the contact design predicts.

Setting a force window

The upper limit is set by the housing, the panel and the user. The lower limit is set by contact stability. Somewhere between them is the window that the design must hold over life, temperature and the permitted number of mates.

For the upper limit, consider the hand force that a technician can apply in the installed position. A connector behind a panel, at arm's length, with no lever, is much harder to mate than the same connector on a bench. If the force is high, add a lever, a screw coupling or a cam, and specify the force at the lever rather than at the contacts.

For the lower limit, think about contact resistance and fretting. A contact that is barely touching will pass a continuity check and then drift. Vibration and thermal cycling cause small movements at the contact interface, and a low normal force allows oxide to build and resistance to rise. The withdrawal force is a useful proxy for normal force, which is why it is tested.

Specify the force at the first mate, after a defined number of mates, and at the temperature extremes if the application is severe. A single room-temperature figure does not cover a connector that runs hot or cold.

A minimum withdrawal force is a quality requirement

The maximum insertion force protects the user and the housing. The minimum withdrawal force protects the electrical joint. Both belong on the drawing.

How to test it

Use a tensile or compression tester with a controlled speed and a free-floating alignment fixture. The fixture should let the connector self-align in the two lateral axes, so that the test measures the connector rather than the rigidity of the machine.

The two common references are EIA-364-13 for mating and unmating forces and IEC 60512-13-1, test 13a, for engaging and separating forces. They define the rate of travel, the preparation and the record. Follow the rate in the standard rather than choosing a convenient one, because force depends on speed.

Record the full force-displacement curve, not only the peak. The curve shows where the seal compresses, where the latch engages and whether the contacts are binding. A single peak number hides the shape of the problem.

Test the finished assembly with the correct cable, the correct backshell and the correct panel mounting. A bare connector on a bench is a different mechanical system from a harness hanging from a panel. If the connector is sealed, test it with the seal fitted and lubricated as specified.

Contact force, resistance and wear

The contact spring provides the normal force. For many small signal contacts that force is in the range of 1 to 3 N, and for power contacts it is higher. The exact value belongs to the contact design, not to a general rule.

More normal force lowers contact resistance and makes the joint more tolerant of vibration and oxide. It also increases insertion force and wear. A high-force contact in a connector that is mated daily will wear its plating sooner than a lower-force design. The right balance depends on the number of mates and the environment.

Plating choice changes the friction. Tin plating is soft and has a relatively high friction coefficient, so a tin contact needs more insertion force than a gold contact of the same geometry. Gold is smoother and more stable at low force, which is one reason it is used on signal contacts that see many mates.

Lubrication can reduce insertion force without changing the spring. A thin, compatible lubricant on the contact and the seal is common in sealed connectors. It must be specified, because the wrong lubricant can swell the seal or attract dust.

The user experience

A connector that is hard to mate will be forced, and forcing damages housings, bent pins and cracked solder joints. A connector that is too easy to mate may not latch, or may feel connected when it is not. The force profile is part of the user interface.

Give the user feedback at the end of travel. An audible or tactile click from a latch, a visual witness line or a secondary lock that only closes when the connector is fully home all reduce half-mated connections. The force at that point should be distinct but not so high that the user stops before the latch engages.

For high circuit counts, a lever or a screw coupling changes the effort and the feel. The specification should then be written at the actuation point, with the mechanical advantage stated. A contact force inside the connector can be correct while the lever effort is unacceptable, or the reverse.

Test with a representative group of users if the connector is hand-mated in the field. A force that is comfortable on a bench can be difficult overhead, in gloves, in the cold or in a restricted space.

Illustrative force bands by application

The table gives starting bands for discussion, not acceptance limits. The real limit depends on the contact system, the circuit count, the seal and the installation. All values are illustrative.

Illustrative mating force bands for connector classes
Connector classTypical circuitsIllustrative insertion forceWhat sets the limit
Small signal connector2 to 1210 to 30 NHand mating and contact normal force
Board-to-board connector20 to 8030 to 70 NPCB support and contact count
Sealed automotive connector8 to 2450 to 120 NSeal compression and lever assist
Industrial power connector3 to 680 to 200 NContact size and cable stiffness
High-current battery connector1 to 4100 to 250 NContact force and touch protection

Illustrative only. Measure the finished connector at the standard test rate and set the acceptance window from the contact design, the housing strength and the installation access.

What to put on the drawing and the test report

State the maximum insertion force and the minimum withdrawal force, each with the test standard, the rate, the number of mates and the temperature. State whether the values apply to the first mate or to a conditioned sample.

Add the alignment condition. A force measured with a free-floating fixture is not the same as a force measured with a rigid fixture and a misaligned panel. If the installation cannot guarantee alignment, the drawing should say so and the test should reproduce it.

Ask for the force-displacement curve with the report. Note the peak, the travel at which it occurs and the force at the latch. If the connector has a seal, record the force with and without it so that the seal contribution is visible.

Finally, link the force to the electrical test. A sample that passes the force window but has a rising contact resistance is not a good connector. The force test and the resistance test belong in the same qualification plan.

  • Maximum insertion force and minimum withdrawal force
  • Test standard, rate and alignment fixture
  • First mate and after a stated number of mates
  • Temperature at test and any conditioning
  • Seal fitted or removed, and lubricant
  • Force-displacement curve with the report
  • Contact resistance before and after the force test

Frequently asked questions

What is a normal insertion force for a connector?

It depends on the contact count, the contact force and the seals. Small signal connectors often sit in the range of 10 to 30 N, while sealed power connectors can need over 100 N or a lever assist. Treat any band as illustrative and test the finished connector.

Why is withdrawal force lower than insertion force?

The latch, the seal and the contact wipe can all add force in one direction and subtract in the other. Friction also changes as the surfaces settle. A lower withdrawal force is normal, but it must stay above the minimum that proves the contacts are still loaded.

Which standard covers connector mating force?

EIA-364-13 covers mating and unmating forces, and IEC 60512-13-1, test 13a, covers engaging and separating forces. Both define the test rate and the record. Use the one named in your product specification.

Can lubrication reduce insertion force?

Yes, a thin compatible lubricant can reduce friction at the contacts and the seal. It must be specified and checked for compatibility with the housing, the seal and the plating. Lubrication does not replace correct contact force.

Sources and further reading

  • EIA-364-13, Mating and Unmating Forces Test Procedure for Electrical Connectors
  • IEC 60512-13-1, Connectors for electronic equipment, tests and measurements, engaging and separating forces
  • IEC 60512-2-1, Connectors for electronic equipment, contact resistance test
QK

Qumek Engineering Desk

Engineering team

The engineering team behind Qumek drawings, DFM notes, tolerances and inspection standards. Every guide is reviewed against the drawings and processes used on live programmes.

Writing a connector force specification?

Send the connector drawing, the circuit count and the installation access. The engineering desk will review the force window, the test method and the contact resistance link.

Send a drawing
More in Lugs →
Lugs9 min read

Crimp vs solder vs bolted terminations

Three ways to end a cable, with different tooling, different failure modes and different answers when the joint has to be repaired on site.

Read