Busbar for EV battery packs: interconnects, fusing and isolation

A pack busbar is a current path, a fuse holder and an insulation component at the same time. The three roles pull the design in different directions.

QKQumek Engineering Desk··9 min read·Updated
t 10Ø 13.0

Key takeaways

  • Separate the cell-to-cell, module-to-module and pack-level runs, because each has a different current, joint and service requirement.
  • The joining method is part of the electrical design: a weld, a bolt and a spring contact all give a different resistance and a different repair path.
  • Fusing and isolation have to be designed with the bar, not added after the current path is fixed.
  • Vibration, thermal expansion and cell tolerance stack decide whether a joint survives the life of the pack.

What a pack busbar does

In an electric vehicle battery pack, the busbar connects cells into modules, modules into strings and strings to the pack terminals. It carries the pack current at the pack voltage, and it often carries the cell voltage sensing path as well. It may also hold the fuse that protects a string, a module or a single cell group.

That combination makes the part more than a conductor. It is a structural element that has to survive vibration. It is a thermal element that has to carry heat away from the cell tabs. It is an insulation element that has to keep the high-voltage system away from the chassis and from a person working on the pack. A design that optimises only the cross-section will miss at least one of those jobs.

Three levels: cell, module and pack

The cell level is the hardest. A cylindrical cell has a small tab or can, a prismatic cell has a flat tab, and a pouch cell has a thin foil tab. The current is high relative to the joint area, the space is tight, and the joint is often made by welding. The busbar here is usually a thin strip or a shaped plate that is welded across a row of tabs.

The module level collects the cells and brings the current to a module terminal. The current is the sum of the cells in parallel, so the bar is wider or thicker, and the joint may be bolted or welded depending on whether the module is serviceable. The pack level connects modules in series and parallel and brings the total current to the pack terminals. This is where the largest sections and the most substantial insulation appear.

Separating the levels makes the drawing clearer. A cell interconnect needs a weld schedule and a tab geometry. A pack busbar needs a terminal interface, a fault rating and a service plan. Mixing the two on one drawing usually produces a part that is over-specified at one end and under-specified at the other.

Joining methods

Laser welding is common for cell tabs and thin busbars. It is fast, it can be automated and it gives a narrow heat-affected zone, but the joint needs clean surfaces, a controlled gap and a fixture that holds the parts together. The weld quality depends on the material combination, the coating and the fit between the tab and the bar.

Bolted joints appear where a module or a pack has to be serviced. They are easier to inspect and replace, but they add height, parts and a torque requirement, and they need a contact face that stays conductive through vibration and thermal cycling. A bolted joint in a pack is usually a deliberate service decision, not a default.

Fusing and current interruption

A pack busbar is often the place where a fuse is placed, because it is already in the current path and it can be sized to the conductor. The fuse may be a separate element bolted or welded to the bar, a narrow section of the bar itself, or a wire bond at the cell level. Each has a different breaking capacity and a different failure mode.

A bar with an integral fuse section is compact and cheap, but the narrow section is a hot spot and its rating has to be checked at the maximum ambient and the maximum continuous current. The section also has to clear the fault current without damaging the insulation or the neighbouring cells. That is a test and calculation question, not a drawing note.

The bar is part of the protection path

If the bar carries a fuse or a fusible section, its current rating and its fault behaviour belong in the same calculation as the protection device.

Insulation, isolation and touch safety

A pack busbar runs at a high voltage relative to the chassis, and the insulation has to be rated for the system voltage, the pollution and the altitude. The busbar is often coated, wrapped or held in a plastic carrier. Each of those is a different insulation solution with a different creepage, clearance and test requirement.

Coating is common because it saves space, but it only counts as insulation where the thickness, continuity and adhesion are specified and verified. A coating that is thin at a weld or a bend is a weak point, and a weld spatter or a sharp edge can create a pinhole. The coating boundary near a terminal is another weak point, because that is where the bare metal has to be accessible for the connection.

The isolation test is the evidence. A dielectric withstand test and an insulation resistance measurement at the pack level show whether the whole assembly, including the bars, the carriers and the joints, meets the requirement. The test voltage and the duration come from the applicable standard and the pack specification, not from a supplier default.

Thermal and mechanical duty

A pack busbar carries a high current in a small space, and the cell tabs are heat sources. The bar can act as a heat spreader, moving heat away from the tabs, or as a heat path into the cell, depending on the geometry and the cooling. A bar that is too thin runs hot and adds resistance. A bar that is too thick adds mass and can make the weld harder.

Vibration is the other design driver. The pack sees road input, and the busbar and its joints have to survive it. A welded joint is rigid and adds stiffness to the tab, which can fatigue the tab if the geometry is wrong. A bolted joint can loosen. A flexible section, a bend or a loop can absorb movement, but it also adds resistance and a place for the insulation to crack.

Inspection and what to send

Inspection should cover the material, the joint, the insulation and the current path. For a welded joint, check the weld nugget or the weld cross-section on a sample, the pull or peel strength and the heat-affected zone. For a bolted joint, check the torque, the contact resistance and the fastener marking. For the bar, check the section, the plating, the bend and the fuse geometry.

A pack busbar drawing should state the material and temper, the plating, the joint method, the fuse rating and its location, the insulation type and thickness, the test voltage and the sample plan. Add the cell or module interface dimensions and the tolerance that the assembly can absorb. Without those, the supplier can make a good bar that does not fit the pack.

Send the pack layout, the cell or module datasheet, the current profile, the fault level, the cooling arrangement and the vibration specification. If the design is new, send the concept and say which interfaces are fixed. A supplier can then propose a joint and a fuse arrangement, and flag the parts that will move the cost.

Interconnect options in a battery pack
LevelTypical jointCurrentWhat to inspect
Cell to cellLaser or ultrasonic weldHigh for the joint areaWeld section, pull strength, tab heat
Module to moduleWelded strap or bolted linkSum of parallel cellsJoint resistance and insulation
Pack terminalsBolted or weldedFull pack currentTorque, contact resistance, plating
Voltage sense tapsWelded wire or small tabVery lowAttachment, routing, strain relief
Fuse linkIntegral section or separate fuseRated to the stringSection, rating, clearing check

The table describes the roles, not a preferred design. The joint and the fuse have to be selected together for the pack current and fault level.

Frequently asked questions

Why are EV busbars often aluminium?

Aluminium is lighter and cheaper per kilogram than copper, and it can be welded directly to aluminium cell tabs. It needs about 1.6 times the cross-section for the same resistance, a joint that breaks the oxide layer and a plating or coating that suits the environment. Copper is used where space or conductivity matters more than weight.

Should a pack busbar be welded or bolted?

Weld when the joint is permanent, the current is high and the space is tight. Bolt when the module or pack has to be serviced or replaced. A bolted joint needs a contact face that stays conductive under vibration, and a torque and contact resistance check in production.

Can the busbar coating be used as the only insulation?

Only where the standard allows it and the coating is specified and verified as solid insulation. A pack also needs clearance and creepage to the chassis, and the coating has to stay continuous at welds, bends and terminal boundaries. The dielectric test at pack level is the evidence.

How is a pack busbar fuse sized?

The fuse has to carry the maximum continuous current at the maximum ambient and clear the fault current within the time the pack can tolerate. If the fuse is an integral section of the bar, its narrowest area and its heat path decide the rating. The bar, joint and fuse should be checked together.

Sources and further reading

  • IEC 60664-1, Insulation coordination for equipment within low-voltage supply systems
  • ISO 6469-1, Electrically propelled road vehicles, safety specifications, rechargeable energy storage system
  • Qumek EV busbar and interconnect reviews
QK

Qumek Engineering Desk

Engineering team

The engineering team behind Qumek drawings, DFM notes, tolerances and inspection standards. Every guide is reviewed against the drawings and processes used on live programmes.

Designing an interconnect for a new pack?

Send the cell or module datasheet, current profile, fault level and pack layout. The engineering desk will review the joint, fuse and insulation before quoting.

Send the pack layout

The Qumek dispatch

One useful email a month

Drawing notes, supplier checks, tariff changes and the questions buyers keep asking. No newsletter filler, no daily drip.

One email a month. No spam, no list sharing.